KB#00883-FLEXlm error -25 when starting or in BLM logfile
Title:
FLEXlm error -25 when starting or in BLM logfile
Description:
The logfile located in the blmgr directory will have a message simlar to:
16:23:28 (basis) Server started on server_name for:PRO5_DEV
16:23:35 (basis) DENIED: "PRO5_DEV" root@server_name (License server does not support this version of this feature (-25,334))
16:23:35 (basis) UNSUPPORTED: "PRO5" (PORT_AT_HOST_PLUS ) root@server_name (License server does not support this feature (-18,327))
Resolution:
This is indicative of the PRO/5 / BBj revision level not matching the license file revision. For example:
a license file for version 2.23 and a PRO/5 executable revision 3.02
a license file for BBj/Pro/5 feature running a PRO/5 version prior to version 4
It also can indicates a conflict between the Client and Server revision levels.
PRO/5 Rev 2.23 connecting to a PRO/5 DataServer Rev 3.01
Last Modified: 01/16/2007 Product: License Manager
BASIS structures five components of their technology into the BBx Generations.