KB#00869-Error 46 on SENDMSG 80 binding to a Data Aware Grid
Title:
Error 46 on SENDMSG 80 binding to a Data Aware Grid
Description:
Using a SELECT statement that has SORTBY clause may return an error 46 when binding the Data Aware Grid using SENDMSG 80. SELECT statements that use a SORTBY clause may need to create temporary files. PRO5 uses the environment variable TMPDIR to determine where these temporary files will be created.
Resolution:
Verify that the TMPDIR environment variable is being set. Data Aware Grids binding to a file being opened via the Data Server require that the TMPDIR variable be set prior to starting the Data Server. This can be achieved by starting the Data Server via a script file. Adequate permissions to the directory specified by the TMPDIR environment variable must exist.
See KB articles 369, 650 for further information on setting the TMPDIR variable.